Configuring The Ambiance Low Voltage Disk Light System

Configuring and Building the Ambiance Low Voltage Disk Light System

Example For Class II Electronic Transformers

Example For Class I Magnetic Transformers

Get Systems is a Two In One with Ambiance Low Voltage Disk Lights

For Single or Dual 60w Max Class II Transformers

(Class II) wire disk lights directly to the transformer, or select disk lights that are available with plugs to be plugged into transformers with outlets. Example: 9858-15 disk light with 9774 lamp.

Example Single Tap Transformers for use on this system: 9454-12, 9457-12
ambiance disk lights

Example for Douple Tap Class II Transformer System use transformers 980175 & 98076
ambiance disk light kits

1. Disk Light
Determine the quantity of disk lights needed.

2. Lamp
Order one lamp per disk light. WARNING: Serious risk of fire exists when mixing 12v lamps with 24v transformers.

3. Transformer
Watts consumed per lamp X the number of lamps = total watts consumed. Determine transformer size based on total watts consumed. Note: If the transformer size is larger than 60w maximum, see lX Track and Cable installation method. Note: Electronic transformers should be operated between the specified rated wattage.

For Transformer – Class 1

how to congigure ambiance magnetic transformer

(Class 1) the following additional components are required:

1. Fused Plug: You will need one fused plug (9488) per disk light. Fused plugs attach directly to Ambiance Lx Lighting system track and cable.

2. Cable: Determine the length of cable required based on the total length of all runs. Additional cable may be necessary, depending upon transformer location.

Example: 144″ + 24″ from run to transformer = 168″ of cable.
Note: Using 10/2 105C cable (indoors only) the maximum wattage per run is limited to 300w for 12v or 500w for 24v
applications.
(For outdoor use, special 12v 105C cable (9373) must be used).

3. Track: Determine the number of track sections required based on the total length of all runs and cable length. Track sections are sold in 4′ lengths and may be cut to desired size. Additional track may be required based on location of transformer and cable length.

Example: 168″ divided by 48″ (track sections) = 4′.

Two in One
Get Two In One with Ambiance Low Voltage Disk Lighting

 

9485 Accent and 9858 Task disk lights can be surface mounted or recessed.

Get Systems is a Two In One with Ambiance Low Voltage Disk Lighting